S7
MEANWELL PB 120W Single Output Power Supply or Battery Charger
MEANWELL PB 120W Single Output Power Supply or Battery Charger
SKU SKU:PB-120P-27P
Share
Features :
- AC input range selected by switch
- Built-in passive PFC function compliance to EN61000-3-2
- With AC ON-OFF switch
- 3 poles AC inlet with fuse holder
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Charger type can be selected (Optional}
- Charger for lead-acid batteries
- 2 color LED loading indicator
- Open frame models available (Without safety approval}
- Low cost, High reliability
SPECIFICATION
MODEL |
PA/PB-120 -13 |
PA/PB-120 -27 |
PA/PB-120 -54 |
||
OUTPUT |
DC VOLTAGE |
13.8V |
27.6V |
55.2V |
|
RATED CURRENT |
7.2A |
4.3A |
2.2A |
||
CURRENT RANGE |
0 ~ 7.2A |
0 ~ 4.3A |
0 ~ 2.2A |
||
RATED POWER |
99.36W |
118.68W |
121.44W |
||
LED INDICATED |
PA series voltage 105% 1% : RED / 105% 1% :GREEN |
||||
PB series load 46% 10% : GREEN / 46% 10% :RED |
|||||
INPUT |
VOLTAGE RANGE |
88 ~ 132VAC / 176 ~ 264VAC selected by switch |
|||
FREQUENCY RANGE |
47 ~ 63Hz |
||||
POWER FACTOR (Typ.) |
>0.65 (with PFC series) |
||||
EFFICIENCY (Typ.) |
73% |
79% |
79% |
||
AC CURRENT (Typ.) |
3A/115VAC 1.5A/230VAC |
||||
INRUSH CURRENT (Typ.) |
COLD START 25A/115VAC 50A/230VAC |
||||
LEAKAGE CURRENT |
<1.5mA / 240VAC |
||||
PROTECTION |
OVERLOAD |
90 ~ 110% rated output power |
|||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|||||
OVER VOLTAGE |
15 ~ 17V |
30 ~ 35V |
60 ~ 66V |
||
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||||
OVER TEMPERATURE |
RTH2 70 10 detect on RTH2 thermistor |
||||
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
|||||
ENVIRONMENT |
WORKING TEMP. |
-10 ~ +45 (Refer to output load derating curve) |
|||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||||
STORAGE TEMP., HUMIDITY |
-20 ~ +85 , 10 ~ 95% RH |
||||
TEMP. COEFFICIENT |
0.05%/ (0 ~ 45 |
|
|||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1, EN60335, EN60335-1, EN60335-2-29 approved |
|||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
||||
EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
||||
HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
||||
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A |
||||
OTHERS |
MTBF |
149.6K hrs min. MIL-HDBK-217F (25 ) |
|||
DIMENSION |
PCB Type:144*90*33mm External case type:180*96*49mm (L*W*H) |
||||
PACKING |
1.1Kg; 16pcs / 17.9Kg / 1.47CUFT(without PFC) 1.24Kg; 16pcs / 20.1Kg / 1.47CUFT(with PFC) |
||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. With PFC I/P range: 95~132VAC/190~264VAC. 6. For open P.C.B. WITH 17.8CFM min. Forced air. |