Skip to product information
1 of 2

S7

MEANWELL HRP Series With PFC

MEANWELL HRP Series With PFC

SKU SKU:HRP-450-24

Regular price $ 237.37 SGD
Regular price $ 254.00 SGD Sale price $ 237.37 SGD
Sale Sold out
Shipping calculated at checkout.
Power
Voltage

HRP-450W

HRP-600W

Features :

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • High efficiency up to 5%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in constant current limiting circuit
  • Built-in cooling Fan ON-OFF control
  • Built-in DC OK signal
  • Built-in remote sense function

Specification:

MODEL

HRP-450-3.3

HRP-450-5

HRP-450-7.5

HRP-450-12

HRP-450-15

HRP-450-24/600-24

HRP-450-36

HRP-450-48

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

3.3V

5V

7.5V

12V

15V

24V

36V

48V

RATED CURRENT

90A

90A

60A

37.5A

30A

18.8A/27A

12.5A

9.5A

CURRENT RANGE

0 ~ 90A

0 ~ 90A

0 ~ 60A

0 ~ 37.5A

0 ~ 30A

0 ~ 18.8A/0~27A

0 ~ 12.5A

0 ~ 9.5A

RATED POWER

297W

450W

450W

450W

450W

451.2W/648W

450W

456W

RIPPLE & NOISE (max.) Note.2

80mVp-p

80mVp-p

100mVp-p

120mVp-p

150mVp-p

150mVp-p

240mVp-p

240mVp-p

VOLTAGE ADJ. RANGE

2.8 ~ 3.8V

4.3 ~ 5.8V

6.8 ~ 9V

10.2 ~ 13.8V

13.5 ~ 18V

21.6 ~ 28.8V

28.8 ~ 39.6V

40.8 ~ 55.2V

VOLTAGE TOLERANCE Note.3

±2.0%

±2.0%

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION

±0.5%

±0.5%

±0.5%

±0.3%

±0.3%

±0.2%

±0.2%

±0.2%

LOAD REGULATION

±1.0%

±1.0%

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

1000ms, 100ms/230VAC             2500ms, 100ms/115VAC at full load

HOLD UP TIME (Typ.)

16ms/230VAC            16ms/115VAC at full load

 

 

 

 

INPUT

VOLTAGE RANGE            Note.5

85 ~ 264VAC           120 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF>0.95/230VAC            PF>0.99/115VAC at full load

EFFICIENCY (Typ.)

80%

83%

86.5%

88%

89%

88%

89%

89.5%

AC CURRENT (Typ.)

5A/115VAC         2.4A/230VAC

INRUSH CURRENT (Typ.)

35A/115VAC           70A/230VAC

LEAKAGE CURRENT

<1.5mA / 240VAC

 

 

 

PROTECTION

 

OVERLOAD

105 ~ 135% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

 

OVER VOLTAGE

3.96 ~ 4.62V

6 ~ 7V

9.4 ~ 10.9V

14.4 ~ 16.8V

18.8 ~ 21.8V

30 ~ 34.8V

41.4 ~ 48.6V

57.6 ~ 67.2V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION

DC OK SIGNAL

PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V

FAN CONTROL (Typ.)

Load 20±10% or RTH2≧50℃ Fan on

 

 

 

ENVIRONMENT

WORKING TEMP.

-40 ~ +70℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH non-condensing

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

 

SAFETY & EMC

(Note 4)

SAFETY STANDARDS

UL62368-1, TUV EN62368-1, EAC TP TC 004 approved

WITHSTAND VOLTAGE

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020

 

OTHERS

MTBF

139.9K hrs min.        MIL-HDBK-217F (25℃)

DIMENSION

218*105*41mm (L*W*H)

PACKING

1.19Kg; 12pcs/15.3Kg/0.82CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on     a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com}

5. Derating may be needed under low input voltages. Please check the derating curve for more details.

6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.

 

View full details