S7
MEANWELL HRP Series With PFC
MEANWELL HRP Series With PFC
SKU SKU:HRP-450-24
Share
Features :
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 5%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Built-in constant current limiting circuit
- Built-in cooling Fan ON-OFF control
- Built-in DC OK signal
- Built-in remote sense function
Specification:
MODEL |
HRP-450-3.3 |
HRP-450-5 |
HRP-450-7.5 |
HRP-450-12 |
HRP-450-15 |
HRP-450-24/600-24 |
HRP-450-36 |
HRP-450-48 |
|
OUTPUT |
DC VOLTAGE |
3.3V |
5V |
7.5V |
12V |
15V |
24V |
36V |
48V |
RATED CURRENT |
90A |
90A |
60A |
37.5A |
30A |
18.8A/27A |
12.5A |
9.5A |
|
CURRENT RANGE |
0 ~ 90A |
0 ~ 90A |
0 ~ 60A |
0 ~ 37.5A |
0 ~ 30A |
0 ~ 18.8A/0~27A |
0 ~ 12.5A |
0 ~ 9.5A |
|
RATED POWER |
297W |
450W |
450W |
450W |
450W |
451.2W/648W |
450W |
456W |
|
RIPPLE & NOISE (max.) Note.2 |
80mVp-p |
80mVp-p |
100mVp-p |
120mVp-p |
150mVp-p |
150mVp-p |
240mVp-p |
240mVp-p |
|
VOLTAGE ADJ. RANGE |
2.8 ~ 3.8V |
4.3 ~ 5.8V |
6.8 ~ 9V |
10.2 ~ 13.8V |
13.5 ~ 18V |
21.6 ~ 28.8V |
28.8 ~ 39.6V |
40.8 ~ 55.2V |
|
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|
LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.3% |
±0.3% |
±0.2% |
±0.2% |
±0.2% |
|
LOAD REGULATION |
±1.0% |
±1.0% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
SETUP, RISE TIME |
1000ms, 100ms/230VAC 2500ms, 100ms/115VAC at full load |
||||||||
HOLD UP TIME (Typ.) |
16ms/230VAC 16ms/115VAC at full load |
||||||||
INPUT |
VOLTAGE RANGE Note.5 |
85 ~ 264VAC 120 ~ 370VDC |
|||||||
FREQUENCY RANGE |
47 ~ 63Hz |
||||||||
POWER FACTOR (Typ.) |
PF>0.95/230VAC PF>0.99/115VAC at full load |
||||||||
EFFICIENCY (Typ.) |
80% |
83% |
86.5% |
88% |
89% |
88% |
89% |
89.5% |
|
AC CURRENT (Typ.) |
5A/115VAC 2.4A/230VAC |
||||||||
INRUSH CURRENT (Typ.) |
35A/115VAC 70A/230VAC |
||||||||
LEAKAGE CURRENT |
<1.5mA / 240VAC |
||||||||
PROTECTION |
OVERLOAD |
105 ~ 135% rated output power |
|||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|||||||||
OVER VOLTAGE |
3.96 ~ 4.62V |
6 ~ 7V |
9.4 ~ 10.9V |
14.4 ~ 16.8V |
18.8 ~ 21.8V |
30 ~ 34.8V |
41.4 ~ 48.6V |
57.6 ~ 67.2V |
|
Protection type : Shut down o/p voltage, re-power on to recover |
|||||||||
OVER TEMPERATURE |
Shut down o/p voltage, recovers automatically after temperature goes down |
||||||||
FUNCTION |
DC OK SIGNAL |
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V |
|||||||
FAN CONTROL (Typ.) |
Load 20±10% or RTH2≧50℃ Fan on |
||||||||
ENVIRONMENT |
WORKING TEMP. |
-40 ~ +70℃ (Refer to "Derating Curve") |
|||||||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||||||||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH non-condensing |
||||||||
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
||||||||
VIBRATION |
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes |
||||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL62368-1, TUV EN62368-1, EAC TP TC 004 approved |
|||||||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
||||||||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
||||||||
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
||||||||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020 |
||||||||
OTHERS |
MTBF |
139.9K hrs min. MIL-HDBK-217F (25℃) |
|||||||
DIMENSION |
218*105*41mm (L*W*H) |
||||||||
PACKING |
1.19Kg; 12pcs/15.3Kg/0.82CUFT |
||||||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com} 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}. |