S7
MEANWELL AD Series Single-Output Switch Mode Power Supply
MEANWELL AD Series Single-Output Switch Mode Power Supply
SKU:AD-55A
Couldn't load pickup availability
Delivery
Delivery
Singapore
1-3 work days ( 90% of Shipments)
For items that are stocked outside Singapore, it takes 7 - 14 work days.
International
7-14 work days.
Pick FEDEX at checkout for reliable and Fast Deliveries.
Taxes
Taxes
Singapore
GST Not Applicable - Prices displayed are final prices.
International
As per importering country's Duties and taxes. To be paid to Carrier or Customs Dept. Importer is responsible for Import Duty and Taxes.
Contact Us
Contact Us
cs@delight.com.sg
Tel: +65 6429 8402
Whatsapp: +65 8900 0895
We admit ! For Technical Clarifications, our AI BOT is Quicker than us. Try it !
Share
Features:
- Universal AC input / Full range
- Protections: Short circuit / Over load / Over voltage
- Battery low and battery polarity protection
- Cooling by free air convection
- 100 % full load burn-in test
- Fixed switching frequency at 45KHz
Specification:
|
MODEL |
AD-55A |
AD-55B |
|||
|
OUTPUT |
OUTPUT NUMBER |
CH1 |
CH2 |
CH1 |
CH2 |
|
DC VOLTAGE |
13.8V |
13.4V |
27.6V |
26.5V |
|
|
RATED CURRENT |
3.5A |
0.23A |
1.8A |
0.16A |
|
|
CURRENT RANGE |
0 ~ 4A |
-------- |
0 ~ 2A |
-------- |
|
|
RATED POWER |
51.38W |
53.92W |
|||
|
RIPPLE & NOISE (max.) Note.2 |
100mVp-p |
-------- |
100mVp-p |
-------- |
|
|
VOLTAGE ADJ. RANGE |
CH1: 12 ~ 14.5V |
CH1: 24 ~ 29V |
|||
|
VOLTAGE TOLERANCE Note.3 |
±1.0% |
-------- |
±1.0% |
-------- |
|
|
LINE REGULATION |
±0.5% |
-------- |
±0.5% |
-------- |
|
|
LOAD REGULATION |
±0.5% |
-------- |
±0.5% |
-------- |
|
|
SETUP, RISE TIME |
800ms, 50ms/230VAC 1600ms, 50ms/115VAC at full load |
||||
|
HOLD UP TIME (Typ.) |
80ms/230VAC 16ms/115VAC at full load |
||||
|
INPUT |
VOLTAGE RANGE |
88 ~ 264VAC 124 ~ 370VDC |
|||
|
FREQUENCY RANGE |
47 ~ 63Hz |
||||
|
EFFICIENCY (Typ.) |
71% |
74% |
|||
|
AC CURRENT (Typ.) |
1.6A/115VAC 1A/230VAC |
||||
|
INRUSH CURRENT (Typ.) |
COLD START 20A/115VAC 40A/230VAC |
||||
|
LEAKAGE CURRENT |
<1mA / 240VAC |
||||
|
PROTECTION |
OVERLOAD |
105 ~ 150% rated output power |
|||
|
Protection type : AC Charging Mode : Hiccup mode, recovers automatically after fault condition is removed UPS Mode : Protected by internal fuse |
|||||
|
OVER VOLTAGE |
CH1:15.87 ~ 18.63V |
CH1:31.74 ~ 37.26V |
|||
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||||
|
BATTERY LOW |
9.5 ~ 11V |
20 ~ 22V |
|||
|
FUNCTION |
DC ALARM SIGNAL(OPTIONAL) |
AC fail CN1 PIN2 |
|||
|
Battery low under charge voltage 82.5%±2% CN1 PIN1 |
|||||
|
Normal 0.8V max. Abnormal 5V±0.5V |
|||||
|
ENVIRONMENT |
WORKING TEMP. |
-10 ~ +60℃ (Refer to "Derating Curve") |
|||
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||||
|
STORAGE TEMP., HUMIDITY |
-20 ~ +85℃, 10 ~ 95% RH |
||||
|
TEMP. COEFFICIENT |
±0.03%/℃ (0~50℃) on CH1 output |
||||
|
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
||||
|
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1, EAC TP TC 004 approved |
|||
|
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
||||
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
||||
|
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
||||
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020 |
||||
|
OTHERS |
MTBF |
304.3K hrs min. MIL-HDBK-217F (25℃) |
|||
|
DIMENSION |
159*97*38mm (L*W*H) |
||||
|
PACKING |
0.5Kg; 24pcs/12.6Kg/0.75CUFT |
||||
|
MODEL |
AD-155A |
AD-155B |
AD-155C |
||||
|
OUTPUT |
OUTPUT NUMBER |
CH1 |
CH2 |
CH1 |
CH2 |
CH1 |
CH2 |
|
DC VOLTAGE |
13.8V |
13.3V |
27.6V |
27.1V |
54V |
53.5V |
|
|
RATED CURRENT |
10.5A |
0.5A |
5A |
0.5A |
2.7A |
0.2A |
|
|
CURRENT RANGE |
0 ~ 11.5A |
0 ~ 0.5A |
0 ~ 5.5A |
0 ~ 0.5A |
0 ~ 2.7A |
0 ~ 0.5A |
|
|
RATED POWER |
151.55W |
151.55W |
156.5W |
||||
|
RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
-------- |
150mVp-p |
-------- |
240mVp-p |
-------- |
|
|
VOLTAGE ADJ. RANGE |
CH1: 12 ~ 14.5V |
CH1: 24 ~ 29V |
CH1: 48 ~ 58V |
||||
|
VOLTAGE TOLERANCE Note.3 |
±2.0% |
-------- |
±1.0% |
-------- |
±1.0% |
-------- |
|
|
LINE REGULATION |
±0.5% |
-------- |
±0.5% |
-------- |
±0.5% |
-------- |
|
|
LOAD REGULATION |
±0.5% |
-------- |
±0.5% |
-------- |
±0.5% |
-------- |
|
|
SETUP, RISE TIME |
1000ms, 90ms/230VAC 2000ms, 90ms/115VAC at full load |
||||||
|
HOLD UP TIME (Typ.) |
24ms/230VAC 20ms/115VAC at full load |
||||||
|
INPUT |
VOLTAGE RANGE |
88 ~ 264VAC 124 ~ 370VDC |
|||||
|
FREQUENCY RANGE |
47 ~ 63Hz |
||||||
|
POWER FACTOR (Typ.) |
PF>0.92 at full load |
||||||
|
EFFICIENCY (Typ.) |
80% |
84% |
84% |
||||
|
AC CURRENT (Typ.) |
2.5A/115VAC 1.5A/230VAC |
||||||
|
INRUSH CURRENT (Typ.) |
COLD START 23A/115VAC 45A/230VAC |
||||||
|
LEAKAGE CURRENT |
<1mA / 240VAC |
||||||
|
PROTECTION |
OVERLOAD |
CH1:105 ~ 135% CH2:0.51 ~ 0.9A rated output power |
|||||
|
Protection type : AC Charging Mode : Constant current limiting, recovers automatically after fault condition is removed UPS Mode : Protected by internal fuse |
|||||||
|
OVER VOLTAGE |
CH1:15.87 ~ 18.63V |
CH1:31.74 ~ 37.26V |
CH1:62.1 ~ 72.9V |
||||
|
Protection type : Shut down o/p voltage, re-power on to recover |
|||||||
|
BATTERY LOW |
10V±0.8V |
19.5V(+1.5V,-1V ) |
39V±2V |
||||
|
ENVIRONMENT |
WORKING TEMP. |
-10 ~ +60℃ (Refer to "Derating Curve") |
|||||
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||||||
|
STORAGE TEMP., HUMIDITY |
-20 ~ +85℃, 10 ~ 95% RH |
||||||
|
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
||||||
|
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
||||||
|
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1, EAC TP TC 004 approved |
|||||
|
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
||||||
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
||||||
|
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
||||||
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020 |
||||||
|
OTHERS |
MTBF |
183.3K hrs min. MIL-HDBK-217F (25℃) |
|||||
|
DIMENSION |
199*110*50mm (L*W*H) |
||||||
|
PACKING |
0.88Kg; 16pcs/15Kg/0.95CUFT |
||||||