S7N2C12F2
ABB AX150-30-11-84 Block Contactor
ABB AX150-30-11-84 Block Contactor
SKU SKU:7320500500170
Regular price
$ 336.00 SGD
Regular price
$ 336.00 SGD
Sale price
$ 336.00 SGD
Unit price
/
per
Share
Technical Details
Lead time 6-7 weeks.
AX150-30-11-84
General Information
-
- Extended Product Type:
- AX150-30-11-84
-
- Product ID:
- 1SFL991074R8411
-
- EAN:
- 7320500500170
-
- Catalog Description:
- AX150-30-11-84 Contactor
-
- Long Description:
- AX150-30-11-84 Contactor
Categories
Ordering
-
- Minimum Order Quantity:
- 1 piece
-
- Customs Tariff Number:
- 85364900
Popular Downloads
-
- Instructions and Manuals:
-
9AKK107492A7060
Dimensions
-
- Product Net Width:
-
102 mm
-
- Product Net Depth / Length:
-
123.5 mm
-
- Product Net Height:
-
148 mm
-
- Product Net Weight:
-
1.9 kg
Technical
-
- Number of Main Contacts NO:
- 3
-
- Number of Main Contacts NC:
- 0
-
- Number of Auxiliary Contacts NO:
- 1
-
- Number of Auxiliary Contacts NC:
- 1
-
- Rated Operational Voltage:
- Main Circuit 1000 V
-
- Rated Frequency (f):
- Main Circuit 50 Hz
-
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 190 A
-
- Rated Operational Current AC-1 (Ie):
- (690 V) 40 °C 190
(690 V) 55 °C 145
(690 V) 70 °C 130
-
- Rated Operational Current AC-3 (Ie):
- (415 V) 55 °C 150 A
(440 V) 55 °C 100 A
(500 V) 55 °C 100 A
(690 V) 55 °C 82 A
(380 / 400 V) 55 °C 150 A
(220 / 230 / 240 V) 55 °C 150
-
- Rated Operational Power AC-3 (Pe):
- (415 V) 75 kW
(440 V) 59 kW
(500 V) 59 kW
(690 V) 75 kW
(380 / 400 V) 75 kW
(220 / 230 / 240 V) 45 kW
-
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
- 8 x Ie AC-3
-
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
- 10 x Ie AC-3
-
- Rated Short-time Withstand Current (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
-
- Maximum Electrical Switching Frequency:
- 300 cycles per hour
-
- Rated Insulation Voltage (Ui):
- acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
-
- Rated Impulse Withstand Voltage (Up):
- 8 kV
-
- Mechanical Durability:
- 10 million
-
- Maximum Mechanical Switching Frequency:
- 3600 cycles per hour
-
- Coil Operating Limits:
- (acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
-
- Rated Control Circuit Voltage (Uc):
- 50 Hz 110 V
60 Hz 110 ... 120 V
-
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
-
- Terminal Type:
- Main Circuit: Bars