For the datasheet click here.
AF305-30-11-13
General Information
-
- Extended Product Type:
- AF305-30-11-13
-
- Product ID:
- 1SFL587002R1311
-
- EAN:
- 7320500481776
-
- Catalog Description:
- AF305-30-11-13 Contactor
-
- Long Description:
- A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, 50/60 Hz and DC
Classifications
-
- Object Classification Code:
- Q
-
- ETIM 4:
- EC000066 - Magnet contactor, AC-switching
-
- ETIM 5:
- EC000066 - Magnet contactor, AC-switching
-
- ETIM 6:
- EC000066 - Power contactor, AC switching
-
- ETIM 7:
- EC000066 - Power contactor, AC switching
-
- UNSPSC:
- 39121529
-
- IDEA Granular Category Code (IGCC):
- 4755 >> Contactors
-
- E-Number (Norway):
- 4117650
-
- E-Number (Sweden):
- 3210163
Container Information
-
- Package Level 1 Units:
- box 1 piece
-
- Package Level 1 Width:
- 263 mm
-
- Package Level 1 Depth / Length:
- 203 mm
-
- Package Level 1 Height:
- 289 mm
-
- Package Level 1 Gross Weight:
- 4.6 kg
-
- Package Level 1 EAN:
- 7320500481776
Technical UL/CSA
-
- Maximum Operating Voltage UL/CSA:
- Main Circuit 1000 V
-
- General Use Rating UL/CSA:
- (600 V AC) 400 A
-
- Horsepower Rating UL/CSA:
- (200 V AC) Three Phase 100 hp
(208 V AC) Three Phase 100 hp
(220 ... 240 V AC) Three Phase 125 hp
(440 ... 480 V AC) Three Phase 250 hp
(550 ... 600 V AC) Three Phase 300 hp
Technical
-
- Number of Main Contacts NO:
- 3
-
- Number of Main Contacts NC:
- 0
-
- Number of Auxiliary Contacts NO:
- 1
-
- Number of Auxiliary Contacts NC:
- 1
-
- Rated Operational Voltage:
- Main Circuit 1000 V
-
- Rated Frequency (f):
- Main Circuit 50/60 Hz
-
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 500 A
-
- Rated Operational Current AC-1 (Ie):
- (1000 V) 40 °C 375 A
(1000 V) 55 °C 325 A
(1000 V) 60 °C 325 A
(1000 V) 70 °C 260 A
(690 V) 40 °C 500 A
(690 V) 55 °C 400 A
(690 V) 70 °C 325 A
-
- Rated Operational Current AC-3 (Ie):
- (1000 V) 55 °C 131 A
(220 / 230 / 240 V) 55 °C 305 A
(380 / 400 V) 55 °C 305 A
(415 V) 55 °C 305 A
(440 V) 55 °C 305 A
(500 V) 55 °C 290 A
(690 V) 55 °C 290 A
-
- Rated Operational Power AC-3 (Pe):
- (1000 V) 185 kW
(220 / 230 / 240 V) 90 kW
(380 / 400 V) 160 kW
(415 V) 160 kW
(440 V) 160 kW
(500 V) 200 kW
(690 V) 250 kW
-
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
- 8 x Ie AC-3
-
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
- 10 x Ie AC-3
-
- Short-Circuit Protective Devices:
- gG Type Fuses 500 A
-
- Rated Short-time Withstand Current (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
-
- Maximum Breaking Capacity:
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3800 A
-
- Maximum Electrical Switching Frequency:
- AC-1 300 cycles per hour
AC-2 / AC-4 150 cycles per hour
AC-3 300 cycles per hour
-
- Rated Operational Current DC-1 (Ie):
- (110 V) 1-Pole, 40 °C 500 A
(220 V) 2 Poles in Series, 40 °C 500 A
(220 V) 3 Poles in Series, 40 °C 500 A
-
- Rated Operational Current DC-3 (Ie):
- (110 V) 2 Poles in Series, 40 °C 400 A
(220 V) 3 Poles in Series, 40 °C 400 A
-
- Rated Operational Current DC-5 (Ie):
- (110 V) 2 Poles in Series, 40 °C 400 A
(220 V) 3 Poles in Series, 40 °C 400 A
-
- Rated Insulation Voltage (Ui):
- acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
-
- Rated Impulse Withstand Voltage (Uimp):
- Main Circuit 8 kV
-
- Mechanical Durability:
- 5 million
-
- Maximum Mechanical Switching Frequency:
- 300 cycles per hour
-
- Coil Operating Limits:
- (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
-
- Rated Control Circuit Voltage (Uc):
- 50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
-
- Coil Consumption:
- Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A
Holding at Max. Rated Control Circuit Voltage DC 4.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 410 W
-
- Operate Time:
- Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
-
- Connecting Capacity Main Circuit:
- Flexible 1 x 16 ... 240 mm²
Rigid Al-Cable 1 x 185 ... 240 mm²
Rigid Cu-Cable 2 x 70 ... 185 mm²
-
- Connecting Capacity Auxiliary Circuit:
- Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 1x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 1 x 1 .... 4 mm²
-
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
-
- Terminal Type:
- Main Circuit: Bars