PHILIPS HF-Performer TLD III
Regular price
$ 24.00 SGD
Regular price
$ 26.00 SGD
Sale price
$ 24.00 SGD
Unit price
per
Shipping calculated at checkout.
Couldn't load pickup availability
General Information
Operating and Electrical
Wiring
System characteristics
Temperature
Mechanical and Housing
Emergency Operation
Approval and Application
Application Code |
III
|
Type Version |
IDC
|
Lamp Type |
TL-D
|
Number of Lamps |
1 piece/unit
|
Number of Products on MCB (16A Type B) (Nom) |
28
|
Automatic Restart |
Yes
|
Input Voltage |
220 to 240 V
|
Input Frequency |
50 to 60 Hz
|
Operating Frequency (Nom) |
45 kHz
|
Ignition Method |
Programmed Start
|
Crestfactor (Max) |
1.7
|
Power Factor 100% Load (Nom) |
0.99
|
Ignition Time (Max) |
0.9 s
|
Mains Voltage Performance (AC) |
-8%-+6%
|
Mains Voltage Safety (AC) |
-10%-+10%
|
Earth Leakage Current (Nom) |
0.5 mA
|
Inrush Current Width |
0.25 ms
|
Constant Wattage Deviation |
-2%/+2%
|
Ballast Factor (Nom) |
1
|
Power Losses (Nom) |
2.5-4.1 W
|
Inrush Current Peak (Max) |
18 A
|
Connector Type Input Terminals |
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
|
Cable Capacity Output Wires Mutual (Nom) |
200 pF
|
Connector Type Output Terminals |
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
|
Cable Length Hot Wiring |
0.75 m
|
Wire Striplength |
8.0-9.0 mm
|
Dual Fixture Master/Slave |
Not applicable [ Master/Slave oper. not applicable]
|
Input Terminal Cross Section |
0.50-1.00 mm²
|
Output Terminal Cross Section |
0.50-1.00 mm²
|
Cable Capacity Output Wires to Earth (Nom) |
200 pF
|
Rated Ballast-Lamp Power |
18 W / 58 W
|
Rated Lamp Power on TL-D |
36/18 W
|
System Power on TL-D |
35.2/19.1 W
|
Lamp Power on TL-D |
31.1/16.6 W
|
Power Loss on TL-D |
4.1/2.5 W
|
Rated Lamp Power on PL-L |
36 W
|
System Power on PL-L |
34.6 W
|
Lamp Power on PL-L |
30.7 W
|
Power Loss on PL-L |
3.9 W
|
T-Ambient (Max) |
60 °C
|
T-Ambient (Min) |
-25 °C
|
T-Storage (Max) |
50 °C
|
T-Storage (Min) |
-40 °C
|
T-Case Lifetime (Nom) |
80 °C
|
T-Case Maximum (Max) |
80 °C
|
T-Ignition (Max) |
60 °C
|
T-Ignition (Min) |
-25 °C
|
Housing |
L 280x30x28
|
Nominal Light Output After 60 Seconds |
100% of EBLF
|
Battery Voltage Lamp Ignition |
186-275 V
|
Normal Operating Voltage (DC) |
220-240 V
|
Battery Voltage Lamp Operation |
186-275
|
Battery Voltage Guaranteed Operation |
176-275 V
|
Battery Voltage Guaranteed Ignition |
186-275 V
|
Emergency Ballast Lumen Factor (EBLF) (Nom) |
100 %
|
Nominal Light Output After 5 Seconds |
50% of EBLF
|
Energy Efficiency Index |
A2 BAT
|
IP Classification |
IP 20 [ Ingress Protection 20]
|
EMI 9 kHz ... 30 MHz |
EN55015
|
EMI 30 MHz ... 1000 MHz |
EN55022 level B
|
Safety Standard |
IEC 61347-2-3
|
Performance Standard |
IEC 60929
|
Quality Standard |
ISO 9000:2000
|
Environmental Standard |
ISO 14001
|
Harmonic Current Emission Standard |
IEC 61000-3-2
|
EMC Immunity Standard |
IEC 61547
|
Vibration Standard |
IEC68-2-6 F c
|
Bumps Standard |
IEC 68-2-29 Eb
|
Humidity Standard |
EN 61347-2-3 clause 11
|
Approval Marks |
CE marking ENEC certificate VDE-EMV certificate |
Temperature Marking |
Yes
|
Emergency Standard |
IEC 60598-2-22
|
Hum And Noise Level |
< 30 dB(A)
|
Reviews