MEANWELL PID Series with PFC
MEANWELL PID Series with PFC
SKU SKU:PID-250A
Share
Features :
- Universal AC input / Full range
- lsolated output & GND for CH1,CH2
- Built-in active PFC function, PF>0.92
- Protections:Short circuit / Overload / Over voltage / Over temperature
- Remote control for CH1
- Peak load 170% for CH1 within 10
- Cooling by free air convection
- 100% full load burn-in test
Specification:
MODEL |
PID-250A |
PID-250B |
PID-250C |
PID-250D |
|||||
OUTPUT |
OUTPUT NUMBER |
CH1 |
CH2 |
CH1 |
CH2 |
CH1 |
CH2 |
CH1 |
CH2 |
DC VOLTAGE |
12V |
5V |
24V |
5V |
36V |
5V |
48V |
5V |
|
RATED CURRENT |
15A(Peak 20A) |
5A |
9.4A(Peak 16.7A) |
5A |
6.3A(Peak 11.1A) |
5A |
4.7A(Peak 8.4A) |
5A |
|
CURRENT RANGE Note.6 |
0 ~ 15A (Peak 20A) |
0 ~ 5A |
0 ~ 9.4A (Peak 16.7A) |
0 ~ 5A |
0 ~ 6.3A (Peak 11.1A) |
0 ~ 5A |
0 ~ 4.7A (Peak 8.4A) |
0 ~ 5A |
|
RATED POWER |
205W |
250.6W |
251.8W |
250.6W |
|||||
RIPPLE & NOISE (max.) Note.2 |
120mVp-p |
50mVp-p |
150mVp-p |
50mVp-p |
200mVp-p |
50mVp-p |
200mVp-p |
50mVp-p |
|
VOLTAGE ADJ. RANGE |
10.8 ~ 13.2V |
4.75 ~ 5.25V |
21.6 ~ 26.4V |
4.75 ~ 5.25V |
32.4 ~ 39.6V |
4.75 ~ 5.25V |
43.2 ~ 52.8V |
4.75 ~ 5.25V |
|
VOLTAGE TOLERANCE Note.3 |
±3.0% |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
|
LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
LOAD REGULATION |
±1.0% |
±2.0% |
±1.0% |
±2.0% |
±1.0% |
±2.0% |
±1.0% |
±2.0% |
|
SETUP, RISE TIME |
2500ms, 60ms/115VAC 1200ms, 60ms/230VAC |
||||||||
HOLD UP TIME (Typ.) |
30ms at full load |
||||||||
INPUT |
VOLTAGE RANGE Note.5 |
90 ~ 264VAC 127 ~ 370VDC |
|||||||
FREQUENCY RANGE |
47 ~ 63Hz |
||||||||
POWER FACTOR |
PF≧0.92/230VAC PF≧0.97/115VAC at full load |
||||||||
EFFICIENCY(Typ.) |
83% |
86% |
86% |
86% |
|||||
AC CURRENT (Typ.) |
3A/115VAC 1.5A/230VAC |
||||||||
INRUSH CURRENT (Typ.) |
COLD START 58A/230VAC |
||||||||
LEAKAGE CURRENT |
<3.5mA / 240VAC |
||||||||
PROTECTION |
OVERLOAD |
CH1: 105 ~ 170% rated output power Normally work within 10 sec and then shut down, re-power on to recover Over 180% rated power or short circuit, constant current limiting within 10 sec and then shut down, re-power on to recover |
|||||||
CH2: 101 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||||||||
OVER VOLTAGE |
13.8 ~ 16.2V |
5.5 ~ 6.75V |
27.6 ~ 32.4V |
5.5 ~ 6.75V |
40 ~ 48V |
5.5~ 6.75V |
54 ~ 64.8V |
5.5 ~ 6.75V |
|
Protection type : Shut down o/p voltage, re-power on to recover for CH1 ; Hiccup mode, recovers automatically afer fault condition is removed for CH2(by zener diode clamp) |
|||||||||
OVER TEMPERATURE |
Shut down o/p voltage(CH1), recovers automatically after temperature goes down |
||||||||
FUNCTION |
REMOTE CONTROL |
CN52 : Open=CH1 & CH2 power on ; Short = CH1 power off, CH2 power on; when CH2 is malfunction, CH1 will be shut down |
|||||||
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +70℃ (Refer to "Derating Curve") |
|||||||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||||||||
STORAGE TEMP., HUMIDITY |
-20 ~ +85℃, 10 ~ 95% RH |
||||||||
TEMP. COEFFICIENT |
±0.05%/℃ (0 ~ 50℃) |
||||||||
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min each along X, Y, Z axes |
||||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL62368-1, TUV EN62368-1, EAC TP TC 004 approved |
|||||||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
||||||||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
||||||||
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
||||||||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020 |
||||||||
OTHERS |
MTBF |
150.4K hrs min. MIL-HDBK-217F (25℃) |
|||||||
DIMENSION |
222*95*40mm (L*W*H) |
||||||||
PACKING |
0.74Kg; 18pcs/14.3Kg/0.88CUFT |
||||||||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.” (as available on http://www.meanwell.com} 5. Derating may be needed under low input voltage. Please check the derating curve for more details. 6. Peak current should reduce to 150% of rated value if the input voltage <110VAC. 7. Heat Sink HS1,HS2,HS3 can not be shorted. 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}. |