1
/
จาก
1
S7
SCHNEIDER NSX100L Basic Frame Circuit Breaker
SCHNEIDER NSX100L Basic Frame Circuit Breaker
SKU:NSX100L
ราคาปกติ
$ 546.00 SGD
ราคาปกติ
$ 589.00 SGD
ราคาโปรโมชัน
$ 546.00 SGD
ค่าจัดส่งที่คำนวณในขั้นตอนการชำระเงิน
ปริมาณ
ไม่สามารถโหลดความพร้อมในการรับสินค้าด้วยตนเองได้
Delivery
Delivery
Singapore
1-3 work days ( 90% of Shipments)
For items that are stocked outside Singapore, it takes 7 - 14 work days.
International
7-14 work days.
Pick FEDEX at checkout for reliable and Fast Deliveries.
Taxes
Taxes
Singapore
GST Not Applicable - Prices displayed are final prices.
International
As per importering country's Duties and taxes. To be paid to Carrier or Customs Dept. Importer is responsible for Import Duty and Taxes.
แผ่นข้อมูล
แผ่นข้อมูล
cs@delight.com.sg
Tel: +65 6429 8402
Whatsapp: +65 8900 0895
We admit ! For Technical Clarifications, our AI BOT is Quicker than us. Try it !
แบ่งปัน
| range |
Compact
|
|
|---|---|---|
| range of product |
NSX100...250
|
|
| product or component type |
Basic frame
|
|
| device short name |
Compact NSX100L
|
|
| device application |
Distribution
|
|
| circuit breaker name |
Compact NSX100L
|
|
| poles description |
3P
|
|
| network type |
AC
|
|
| network frequency |
50/60 Hz
|
|
| [In] rated current |
100 A at 40 °C
|
|
| [Ui] rated insulation voltage |
800 V AC 50/60 Hz conforming to IEC 60947-2
|
|
| [Uimp] rated impulse withstand voltage |
8 kV conforming to IEC 60947-2
|
|
| [Ue] rated operational voltage |
690 V AC 50/60 Hz conforming to IEC 60947-2
|
|
| breaking capacity code |
L
|
|
| breaking capacity |
130 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
150 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
|
| [Ics] rated service breaking capacity |
130 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
150 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
|
| suitability for isolation |
Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2 |
|
| utilisation category |
Category A
|
|
| pollution degree |
3 conforming to IEC 60947-1
|
| control type |
Toggle
|
|
|---|---|---|
| mounting mode |
Fixed
|
|
| mounting support |
Backplate
|
|
| upside connection |
Front
|
|
| downside connection |
Front
|
|
| protection type |
Without protection
|
|
| mechanical durability |
50000 cycles conforming to IEC 60947-2
|
|
| electrical durability |
10000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-2
20000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-2 30000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2 50000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2 |
|
| connection pitch |
35 mm
|
|
| height |
161 mm
|
|
| width |
105 mm
|
|
| depth |
86 mm
|
| standards |
IEC 60947-2
EN 60947-2 UL 508 |
|
|---|---|---|
| product certifications |
CSA
UL |
|
| IP degree of protection |
IP40 conforming to IEC 60529
|
|
| IK degree of protection |
IK07 conforming to IEC 62262
|
|
| ambient air temperature for operation |
-35…70 °C
|
|
| ambient air temperature for storage |
-55…85 °C
|
| Sustainable offer status |
Green Premium product
|
|
|---|---|---|
| EU RoHS Directive |
Compliant
EU RoHS Declaration |
|
| Mercury free |
Yes
|
|
| RoHS exemption information | ||
| China RoHS Regulation |
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information |
|
| Environmental Disclosure | ||
| Circularity Profile | ||
| WEEE |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
|