E5
PHILIPS HF-Selectalume TL5 Flourescent Ballast x12PCs
PHILIPS HF-Selectalume TL5 Flourescent Ballast x12PCs
SKU SKU:913713042966
ราคาปกติ
$ 240.00 SGD
ราคาปกติ
$ 240.00 SGD
ราคาโปรโมชัน
$ 240.00 SGD
ราคาต่อหน่วย
/
ต่อ
สต็อกสินค้าเหลือน้อย: เหลือ 1 ชิ้น
แบ่งปัน
General Information
Operating and Electrical
Wiring
System characteristics
Temperature
Mechanical and Housing
Emergency Operation
Approval and Application
Application Code |
HE II
|
Type Version |
-
|
Lamp Type |
TL5
|
Number of Lamps |
1/2/(3/4) piece/unit
|
Number of Products on MCB (16A Type B) (Nom) |
28
|
Automatic Restart |
Yes
|
Input Voltage |
220 to 240 V
|
Input Frequency |
50 to 60 Hz
|
Operating Frequency (Nom) |
45 kHz
|
Crestfactor (Nom) |
1.7
|
Power Factor 100% Load (Nom) |
0.99
|
Preheat Time |
0.5 s
|
Mains Voltage Performance (AC) |
202-254V-8%-+6%
|
Mains Voltage Safety (AC) |
198-264V-10%-+10%
|
Earth Leakage Current (Max) |
0.5 mA
|
Inrush Current Width |
0.25 ms
|
Ballast Factor (Nom) |
1
|
Power Losses (Nom) |
2.0-3.5 W
|
Inrush Current Peak (Max) |
24 A
|
Connector Type Input Terminals |
WAGO 744 connector
|
Cable Capacity Output Wires Mutual (Max) |
200 pF
|
Connector Type Output Terminals |
WAGO 744 connector [ Suitable for manual wiring]
|
Cable Length Hot Wiring |
0.75 m
|
Wire Striplength |
8.0-9.0 mm
|
Dual Fixture Master/Slave |
Possible, lamp wires 2m max. length [ Master/Slave operation possible]
|
Input Terminal Cross Section |
0.50-1.00 mm²
|
Output Terminal Cross Section |
0.50-1.00 mm²
|
Cable Capacity Cold Output Wires - Earth (Max) |
200 pF
|
Cable Capacity Hot Output Wires - Earth (Max) |
200 pF
|
Rated Ballast-Lamp Power |
14-35 W / 14-28 W / 35 W / 49 W / 54 W
|
Rated Lamp Power on TL5 HE |
14/35 W
|
System Power on TL5 HE |
16.7/40.5 W
|
Lamp Power on TL5 HE |
14.7/37.0 W
|
Power Loss on TL5 HE |
2.0/3.5 W
|
T-Ambient (Max) |
55 °C
|
T-Ambient (Min) |
-20 °C
|
T-Storage (Max) |
50 °C
|
T-Storage (Min) |
-40 °C
|
T-Case Lifetime (Nom) |
75 °C
|
T-Case Maximum (Max) |
75 °C
|
Housing |
L360x30x22
|
Nominal Light Output After 60 Seconds |
100% of EBLF
|
Normal Operating Voltage (DC) |
220-240 V
|
Battery Voltage Guaranteed Operation |
176-275 V
|
Battery Voltage Guaranteed Ignition |
186-275 V
|
Emergency Ballast Lumen Factor (EBLF) (Nom) |
100 %
|
Nominal Light Output After 5 Seconds |
50% of EBLF
|
Energy Efficiency Index |
A2 BAT
|
IP Classification |
IP 20 [ Ingress Protection 20]
|
EMI 9 kHz ... 30 MHz |
EN55015
|
Vibration Standard |
IEC68-2-6 F c
|
Bumps Standard |
IEC 68-2-29 Eb
|
Approval Marks |
CE marking ENEC certificate CCC certificate C-Tick certificate TISI marking SIRIM approval CCC certificate |
Hum And Noise Level |
30 dB(A)
|