PHILIPS HF-R TL5/PLL Flourescent Ballast x12PCs
PHILIPS HF-R TL5/PLL Flourescent Ballast x12PCs
SKU:913700633166
ราคาปกติ
$ 1,025.31 SGD
ราคาปกติ
$ 1,097.14 SGD
ราคาโปรโมชัน
$ 1,025.31 SGD
ค่าจัดส่งที่คำนวณในขั้นตอนการชำระเงิน
สต็อกสินค้าเหลือน้อย: เหลือ 1 ชิ้น
ปริมาณ
ไม่สามารถโหลดความพร้อมในการรับสินค้าด้วยตนเองได้
Delivery
Delivery
Singapore
1-3 work days ( 90% of Shipments)
For items that are stocked outside Singapore, it takes 7 - 14 work days.
International
7-14 work days.
Pick FEDEX at checkout for reliable and Fast Deliveries.
Taxes
Taxes
Singapore
GST Not Applicable - Prices displayed are final prices.
International
As per importering country's Duties and taxes. To be paid to Carrier or Customs Dept. Importer is responsible for Import Duty and Taxes.
แผ่นข้อมูล
แผ่นข้อมูล
cs@delight.com.sg
Tel: +65 6429 8402
Whatsapp: +65 8900 0895
We admit ! For Technical Clarifications, our AI BOT is Quicker than us. Try it !
แบ่งปัน
General Information
Operating and Electrical
Wiring
System characteristics
Temperature
Controls and Dimming
Mechanical and Housing
Emergency Operation
Approval and Application
| Application Code |
EII
|
| Type Version |
mk2
|
| Lamp Type |
TL5/PL-L
|
| Number of Lamps |
2 piece/unit
|
| Number of Products on MCB (16A Type B) (Nom) |
28
|
| Automatic Restart |
Yes
|
| Input Voltage |
220 to 240 V
|
| Input Frequency |
50 to 60 Hz
|
| Operating Frequency (Max) |
95 kHz
|
| Operating Frequency (Min) |
45 kHz
|
| Ignition Method |
Warm Start
|
| Crestfactor (Max) |
1.7
|
| Power Factor 100% Load (Nom) |
0.99
|
| Ignition Time (Max) |
0.2 s
|
| Mains Voltage Performance (AC) |
-8%-+6%
|
| Mains Voltage Safety (AC) |
-10%-+10%
|
| Earth Leakage Current (Max) |
0.5 mA
|
| Inrush Current Width |
0.25 ms
|
| Power Losses (Nom) |
7.3 W
|
| Inrush Current Peak (Max) |
27 A
|
| Connector Type Input Terminals |
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
|
| Connector Type Output Terminals |
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
|
| Connector Type Control Input Terminals |
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
|
| Wire Striplength |
8.0-9.0 mm
|
| Dual Fixture Master/Slave |
- [ not specified]
|
| Control Input Terminal Cross Section |
0.50-1.00 mm²
|
| Input Terminal Cross Section |
0.50-1.00 mm²
|
| Output Terminal Cross Section |
0.50-1.00 mm²
|
| Auto Insert (ALF/ADS) Wire Cross Section |
0.5 mm²
|
| Rated Ballast-Lamp Power |
24 W
|
| T-Ambient (Max) |
50 °C
|
| T-Ambient (Min) |
-20 °C
|
| T-Storage (Max) |
80 °C
|
| T-Storage (Min) |
-25 °C
|
| Stable Lamp Operation Temperature |
Not Specified
|
| T-Ignition (Max) |
50 °C
|
| T-Ignition (Min) |
0 °C
|
| Control Interface |
1-10V
|
| Regulating Level Power |
1%-100%
|
| Control Input Protection |
Yes (Basic insulation)
|
| Housing |
L 359x30x22
|
| Battery Voltage Lamp Ignition |
196 V
|
| Battery Voltage Lamp Operation |
154-276
|
| Energy Efficiency Index |
A1 BAT
|
| IP Classification |
IP 20 [ Ingress Protection 20]
|
| EMI 9 kHz ... 30 MHz |
EN55015
|
| EMI 30 MHz ... 1000 MHz |
EN55022 level B
|
| Safety Standard |
IEC 61347-2-3
|
| Performance Standard |
IEC 60929
|
| Quality Standard |
ISO 9000:2000
|
| Environmental Standard |
ISO 14001
|
| Harmonic Current Emission Standard |
IEC 61000-3-2
|
| EMC Immunity Standard |
IEC 61547
|
| Vibration Standard |
IEC68-2-6 F c
|
| Bumps Standard |
IEC 68-2-29 Eb
|
| Humidity Standard |
EN 61347-2-3 clause 11
|
| Approval Marks |
CE marking ENEC certificate VDE-EMV certificate |
| Temperature Marking |
Yes
|
| Emergency Standard |
IEC 60598-2-22
|
| Hum And Noise Level |
Inaudible
|