1
/
จาก
2
K5K6
PHILIPS HF-R PL-T/C EII 220-240V 50/60Hz
PHILIPS HF-R PL-T/C EII 220-240V 50/60Hz
SKU SKU:913700680166
ราคาปกติ
$ 70.00 SGD
ราคาปกติ
$ 72.00 SGD
ราคาโปรโมชัน
$ 70.00 SGD
ราคาต่อหน่วย
/
ต่อ
ค่าจัดส่งที่คำนวณในขั้นตอนการชำระเงิน
ไม่สามารถโหลดความพร้อมในการรับสินค้าด้วยตนเองได้
แบ่งปัน
General Information
Operating and Electrical
Wiring
System characteristics
Temperature
Controls and Dimming
Mechanical and Housing
Emergency Operation
Approval and Application
| Application Code |
EII
|
| Type Version |
mk3
|
| Lamp Type |
PL-T/C
|
| Number of Lamps |
2 piece/unit
|
| Number of Products on MCB (16A Type B) (Nom) |
28
|
| Automatic Restart |
Yes
|
| Input Voltage |
220 to 240 V
|
| Input Frequency |
50 to 60 Hz
|
| Operating Frequency (Max) |
100 kHz
|
| Operating Frequency (Min) |
40 kHz
|
| Ignition Method |
Programmed Start
|
| Crestfactor (Max) |
1.7
|
| Power Factor 100% Load (Nom) |
0.95
|
| Mains Voltage Performance (AC) |
-8%-+6%
|
| Mains Voltage Safety (AC) |
-10%-+10%
|
| Earth Leakage Current (Max) |
0.5 mA
|
| Inrush Current Width |
0.35 ms
|
| Constant Wattage Deviation |
-2%/+2%
|
| Ballast Factor (Nom) |
1.0
|
| Inrush Current Peak (Max) |
28 A
|
| Connector Type Input Terminals |
Insert
|
| Cable Capacity Output Wires Mutual (Nom) |
30 pF
|
| Connector Type Output Terminals |
Insert
|
| Connector Type Control Input Terminals |
Insert
|
| Wire Striplength |
7.5-8.5 mm
|
| Dual Fixture Master/Slave |
Not applicable [ Master/Slave oper. not applicable]
|
| Control Input Terminal Cross Section |
0.50-1.50 mm²
|
| Input Terminal Cross Section |
0.50-1.50 mm²
|
| Output Terminal Cross Section |
0.50-1.50 mm²
|
| Cable Capacity Output Wires to Earth (Nom) |
75 pF
|
| Rated Ballast-Lamp Power |
18 W / 26 W
|
| T-Ambient (Max) |
50 °C
|
| T-Ambient (Min) |
-20 °C
|
| T-Storage (Max) |
80 °C
|
| T-Storage (Min) |
-25 °C
|
| T-Case Lifetime (Nom) |
65 °C
|
| T-Case Maximum (Max) |
75 °C
|
| Stable Lamp Operation Temperature |
Not Specified
|
| Control Interface |
1-10V
|
| Regulating Level Power |
1%-100%
|
| Control Input Protection |
Yes (Basic insulation)
|
| Housing |
S 123x79x33
|
| Battery Voltage Lamp Ignition |
198-254 V
|
| Battery Voltage Lamp Operation |
176-254
|
| Energy Efficiency Index |
A1 BAT
|
| IP Classification |
IP 20 [ Ingress Protection 20]
|
| EMI 9 kHz ... 30 MHz |
EN55015
|
| EMI 30 MHz ... 1000 MHz |
EN55022 level B
|
| Safety Standard |
IEC 61347-2-3
|
| Performance Standard |
IEC 60929
|
| Quality Standard |
ISO 9000:2000
|
| Environmental Standard |
ISO 14001
|
| Harmonic Current Emission Standard |
IEC 61000-3-2
|
| EMC Immunity Standard |
IEC 61547
|
| Vibration Standard |
IEC68-2-6 F c
|
| Bumps Standard |
IEC 68-2-29 Eb
|
| Humidity Standard |
EN 61347-2-3 clause 11
|
| Approval Marks |
CE marking ENEC certificate VDE-EMV certificate |
| Temperature Marking |
Not specified
|
| Emergency Standard |
IEC 60598-2-22
|
| Hum And Noise Level |
Inaudible
|