Philips HF-Performer TLD III 1x18W Electronic Ballast is a high-efficiency lighting control gear designed for T8 fluorescent lamps. Built with advanced high-frequency technology, it ensures energy savings, reliable ignition, and longer lamp life.

This ballast operates at high frequency (~45 kHz), reducing flicker and improving lighting comfort. It is ideal for commercial and industrial lighting systems where consistent performance and low energy consumption are essential.

With a slim and robust design, the HF-Performer III series complies with international safety standards and offers automatic restart, high power factor, and low energy losses.

General Information

Parameter Details
Application Code III
Type Version IDC
Lamp Type TL-D (T8 Fluorescent)
Number of Lamps 1
Products on MCB (16A Type B) 28 (Nominal)
Automatic Restart Yes

Operating & Electrical

Parameter Details
Input Voltage 220–240 V
Input Frequency 50–60 Hz
Operating Frequency 45 kHz (Nominal)
Ignition Method Programmed Start
Crest Factor (Max) 1.7
Power Factor (Nominal) 0.99
Ignition Time (Max) 0.9 s
Mains Voltage Performance -8% to +6%
Mains Voltage Safety -10% to +10%
Earth Leakage Current 0.5 mA
Inrush Current Width 0.25 ms
Constant Wattage Deviation -2% / +2%
Ballast Factor 1
Power Losses 2.5 – 4.1 W
Inrush Current Peak 18 A

Wiring

Parameter Details
Input Connector Type WAGO 251 universal connector
Output Connector Type WAGO 251 universal connector
Cable Length (Hot Wiring) 0.75 m
Wire Strip Length 8.0 – 9.0 mm
Input Terminal Cross Section 0.50 – 1.00 mm²
Output Terminal Cross Section 0.50 – 1.00 mm²
Cable Capacity (Mutual) 200 pF
Cable Capacity to Earth 200 pF
Dual Fixture Operation Not applicable

System Characteristics

Parameter TL-D Lamp PL-L Lamp
Rated Ballast-Lamp Power 18W / 58W 36W
Rated Lamp Power 36W / 18W 36W
System Power 35.2 / 19.1 W 34.6 W
Lamp Power 31.1 / 16.6 W 30.7 W
Power Loss 4.1 / 2.5 W 3.9 W

Temperature

Parameter Details
Ambient Temperature (Max) 60°C
Ambient Temperature (Min) -25°C
Storage Temperature (Max) 50°C
Storage Temperature (Min) -40°C
Case Temperature (Nominal/Max) 80°C
Ignition Temperature Range -25°C to 60°C

Mechanical & Housing

Parameter Details
Housing Dimensions 280 × 30 × 28 mm

Emergency Operation

Parameter Details
Light Output after 5 sec 50% of EBLF
Light Output after 60 sec 100% of EBLF
Battery Voltage (Ignition) 186–275 V
Battery Voltage (Operation) 186–275 V
Guaranteed Operation Voltage 176–275 V
Guaranteed Ignition Voltage 186–275 V
Emergency Ballast Lumen Factor 100%
DC Operating Voltage 220–240 V

Approval & Application

Parameter Details
Energy Efficiency Index A2 BAT
IP Rating IP20
EMI Standard (9 kHz–30 MHz) EN55015
EMI Standard (30 MHz–1000 MHz) EN55022 Level B
Safety Standard IEC 61347-2-3
Performance Standard IEC 60929
Quality Standard ISO 9000:2000
Environmental Standard ISO 14001
Harmonic Standard IEC 61000-3-2
EMC Immunity IEC 61547
Vibration Standard IEC68-2-6 Fc
Bump Standard IEC 68-2-29 Eb
Humidity Standard EN 61347-2-3 Clause 11
Certifications CE, ENEC, VDE-EMV
Emergency Standard IEC 60598-2-22
Noise Level < 30 dB(A)
Temperature Marking Yes