General Information
Operating and Electrical
Wiring
System characteristics
Temperature
Mechanical and Housing
Emergency Operation
Approval and Application
| Application Code |
III
|
| Type Version |
IDC
|
| Lamp Type |
TL5 HE / TL5 HO
|
| Number of Lamps |
1/2/3 piece/unit
|
| Number of Products on MCB (16A Type B) (Nom) |
28
|
| Automatic Restart |
Yes
|
| Input Voltage |
220 to 240 V
|
| Input Frequency |
50 to 60 Hz
|
| Operating Frequency (Nom) |
45 kHz
|
| Ignition Method |
Programmed Start
|
| Crestfactor (Max) |
1.7
|
| Power Factor 100% Load (Nom) |
0.99
|
| Ignition Time (Max) |
0.9 s
|
| Mains Voltage Performance (AC) |
-8%-+6%
|
| Mains Voltage Safety (AC) |
-10%-+10%
|
| Earth Leakage Current (Nom) |
0.5 mA
|
| Inrush Current Width |
0.25 ms
|
| Constant Wattage Deviation |
-2%/+2%
|
| Ballast Factor (Nom) |
1.07
|
| Power Losses (Nom) |
2.0-3.0 W
|
| Inrush Current Peak (Max) |
24 A
|
| Connector Type Input Terminals |
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
|
| Cable Capacity Output Wires Mutual (Nom) |
200 pF
|
| Connector Type Output Terminals |
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
|
| Cable Length Hot Wiring |
0.75 m
|
| Wire Striplength |
8.0-9.0 mm
|
| Dual Fixture Master/Slave |
Not applicable [ Master/Slave oper. not applicable]
|
| Input Terminal Cross Section |
0.50-1.00 mm²
|
| Output Terminal Cross Section |
0.50-1.00 mm²
|
| Cable Capacity Output Wires to Earth (Nom) |
200 pF
|
| Rated Ballast-Lamp Power |
14-35 W / 24 W / 49 W / 54 W
|
| Rated Lamp Power on TL5 HE |
14/35 W
|
| System Power on TL5 HE |
16.0/39.5 W
|
| Lamp Power on TL5 HE |
14.0/36.5 W
|
| Power Loss on TL5 HE |
2.0/3.0 W
|
| T-Ambient (Max) |
60 °C
|
| T-Ambient (Min) |
-25 °C
|
| T-Storage (Max) |
80 °C
|
| T-Storage (Min) |
-40 °C
|
| T-Case Lifetime (Nom) |
80 °C
|
| T-Case Maximum (Max) |
80 °C
|
| T-Ignition (Max) |
50 °C
|
| T-Ignition (Min) |
-25 °C
|
| Housing |
L360x30x22
|
| Nominal Light Output After 60 Seconds |
100% of EBLF
|
| Battery Voltage Lamp Ignition |
186-275 V
|
| Normal Operating Voltage (DC) |
220-240 V
|
| Battery Voltage Lamp Operation |
186-275
|
| Battery Voltage Guaranteed Operation |
176-275 V
|
| Battery Voltage Guaranteed Ignition |
186-275 V
|
| Emergency Ballast Lumen Factor (EBLF) (Nom) |
100 %
|
| Nominal Light Output After 5 Seconds |
50% of EBLF
|
| Energy Efficiency Index |
A2 BAT
|
| IP Classification |
IP 20 [ Ingress Protection 20]
|
| EMI 9 kHz ... 30 MHz |
EN55015
|
| EMI 30 MHz ... 1000 MHz |
-
|
| Safety Standard |
IEC 61347-2-3
|
| Performance Standard |
IEC 60929
|
| Quality Standard |
ISO 9000:2000
|
| Environmental Standard |
ISO 14001
|
| Harmonic Current Emission Standard |
IEC 61000-3-2
|
| EMC Immunity Standard |
IEC 61547
|
| Vibration Standard |
IEC68-2-6 F c
|
| Bumps Standard |
IEC 68-2-29 Eb
|
| Humidity Standard |
EN 61347-2-3 clause 11
|
| Approval Marks |
CE marking ENEC certificate VDE-EMV certificate |
| Temperature Marking |
Yes
|
| Emergency Standard |
IEC 60598-2-22
|
| Hum And Noise Level |
< 30 dB(A)
|