ข้ามไปยังข้อมูลสินค้า
1 จาก 1

S7

MEANWELL SPV Series With PFC

MEANWELL SPV Series With PFC

SKU:SPV-300-12

ราคาปกติ $ 142.00 SGD
ราคาปกติ $ 155.00 SGD ราคาโปรโมชัน $ 142.00 SGD
ลดราคา ขายหมดแล้ว
ค่าจัดส่งที่คำนวณในขั้นตอนการชำระเงิน
Power
Voltage

ปริมาณ
Request For Quote

Delivery

Singapore

1-3 work days ( 90% of Shipments)

For items that are stocked outside Singapore, it takes 7 - 14 work days.

International

7-14 work days.

Pick FEDEX at checkout for reliable and Fast Deliveries.

Taxes

Singapore

GST Not Applicable - Prices displayed are final prices.

International

As per importering country's Duties and taxes. To be paid to Carrier or Customs Dept. Importer is responsible for Import Duty and Taxes.

แผ่นข้อมูล

cs@delight.com.sg
Tel: +65 6429 8402
Whatsapp: +65 8900 0895

We admit ! For Technical Clarifications, our AI BOT is Quicker than us. Try it !

Datasheet

Features :

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Forced air cooling by built-in DC Fan
  • Output voltage programmable from 20~110% by 1~5.5VDC external control signal
  • Built-in remote ON-OFF control
  • Built-in fan speed control
  • Fixed switching frequency at 100KHz

Specification:

MODEL

SPV-300-12

SPV-300-24

SPV-300-48

 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE

12V

24V

48V

RATED CURRENT

25A

12.5A

6.25A

CURRENT RANGE

0 ~ 25A

0 ~ 12.5A

0 ~ 6.25A

RATED POWER

300W

300W

300W

RIPPLE & NOISE (max.) Note.2

150mVp-p

150mVp-p

240mVp-p

VOLTAGE ADJ. RANGE

10.8 ~ 13.2V

20 ~ 26.4V

41 ~ 52.8V

VOLTAGE TOLERANCE Note.3

±1.0%

±1.0%

±1.0%

LINE REGULATION

±0.3%

±0.2%

±0.2%

LOAD REGULATION

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

800ms, 50ms/230VAC             2500ms, 50ms/115VAC at full load

HOLD UP TIME (Typ.)

16ms/230VAC            16ms/115VAC at full load

 

 

 

 

INPUT

VOLTAGE RANGE            Note.5

88 ~ 264VAC           124 ~ 370VDC

FREQUENCY RANGE

47 ~ 63Hz

POWER FACTOR (Typ.)

PF>0.95/230VAC            PF>0.98/115VAC at full load

EFFICIENCY (Typ.)

83.5%

85%

86.5%

AC CURRENT (Typ.)

3.6A/115VAC           1.8A/230VAC

INRUSH CURRENT (Typ.)

20A/115VAC            45A/230VAC

LEAKAGE CURRENT

<1mA / 240VAC

 

 

 

PROTECTION

 

OVERLOAD

105 ~ 135% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

 

OVER VOLTAGE

13.8 ~ 16.2V

27.6 ~ 32.4V

57.6 ~ 67.2V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

Shut down o/p voltage, recovers automatically after temperature goes down

 

FUNCTION

REMOTE CONTROL

4 ~ 10VDC power off, <0 ~ 0.8VDC power on

OUTPUT VOLTAGE TRIM

2.4 ~ 13.2V

4.8 ~ 26.4V

9.6 ~ 52.8V

 

 

ENVIRONMENT

WORKING TEMP.

-20 ~ +65℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH non-condensing

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

 

 

 

SAFETY EMC

(Note 4)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY STANDARDS

UL60950-1, TUV EN60950-1, EAC TP TC 004 approved

WITHSTAND VOLTAGE

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020

 

OTHERS

MTBF

207K hrs min.        MIL-HDBK-217F (25℃)

DIMENSION

215*115*50mm (L*W*H)

PACKING

1.1Kg; 12pcs/14Kg/0.92CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on     a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com}

5. Derating may be needed under low input voltages. Please check the derating curve for more details.

6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}.

ดูรายละเอียดทั้งหมด