Features :
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Forced air cooling by built-in DC Fan
- Output voltage programmable from 20~110% by 1~5.5VDC external control signal
- Built-in remote ON-OFF control
- Built-in fan speed control
- Fixed switching frequency at 100KHz
Specification:
|
MODEL |
SPV-300-12 |
SPV-300-24 |
SPV-300-48 |
|
|
OUTPUT |
DC VOLTAGE |
12V |
24V |
48V |
|
RATED CURRENT |
25A |
12.5A |
6.25A |
|
|
CURRENT RANGE |
0 ~ 25A |
0 ~ 12.5A |
0 ~ 6.25A |
|
|
RATED POWER |
300W |
300W |
300W |
|
|
RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
150mVp-p |
240mVp-p |
|
|
VOLTAGE ADJ. RANGE |
10.8 ~ 13.2V |
20 ~ 26.4V |
41 ~ 52.8V |
|
|
VOLTAGE TOLERANCE Note.3 |
±1.0% |
±1.0% |
±1.0% |
|
|
LINE REGULATION |
±0.3% |
±0.2% |
±0.2% |
|
|
LOAD REGULATION |
±0.5% |
±0.5% |
±0.5% |
|
|
SETUP, RISE TIME |
800ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load |
|||
|
HOLD UP TIME (Typ.) |
16ms/230VAC 16ms/115VAC at full load |
|||
|
INPUT |
VOLTAGE RANGE Note.5 |
88 ~ 264VAC 124 ~ 370VDC |
||
|
FREQUENCY RANGE |
47 ~ 63Hz |
|||
|
POWER FACTOR (Typ.) |
PF>0.95/230VAC PF>0.98/115VAC at full load |
|||
|
EFFICIENCY (Typ.) |
83.5% |
85% |
86.5% |
|
|
AC CURRENT (Typ.) |
3.6A/115VAC 1.8A/230VAC |
|||
|
INRUSH CURRENT (Typ.) |
20A/115VAC 45A/230VAC |
|||
|
LEAKAGE CURRENT |
<1mA / 240VAC |
|||
|
PROTECTION |
OVERLOAD |
105 ~ 135% rated output power |
||
|
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||
|
OVER VOLTAGE |
13.8 ~ 16.2V |
27.6 ~ 32.4V |
57.6 ~ 67.2V |
|
|
Protection type : Shut down o/p voltage, re-power on to recover |
||||
|
OVER TEMPERATURE |
Shut down o/p voltage, recovers automatically after temperature goes down |
|||
|
FUNCTION |
REMOTE CONTROL |
4 ~ 10VDC power off, <0 ~ 0.8VDC power on |
||
|
OUTPUT VOLTAGE TRIM |
2.4 ~ 13.2V |
4.8 ~ 26.4V |
9.6 ~ 52.8V |
|
|
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +65℃ (Refer to "Derating Curve") |
||
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
|||
|
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH non-condensing |
|||
|
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
|||
|
SAFETY EMC (Note 4) |
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
||
|
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1, EAC TP TC 004 approved |
|||
|
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
|||
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
|||
|
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
|||
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A, EAC TP TC 020 |
|||
|
OTHERS |
MTBF |
207K hrs min. MIL-HDBK-217F (25℃) |
||
|
DIMENSION |
215*115*50mm (L*W*H) |
|||
|
PACKING |
1.1Kg; 12pcs/14Kg/0.92CUFT |
|||
|
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com} 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}. |
|||