S7
MEANWELL PB 120W Single Output Power Supply or Battery Charger
MEANWELL PB 120W Single Output Power Supply or Battery Charger
SKU:PB-120P-27P
ไม่สามารถโหลดความพร้อมในการรับสินค้าด้วยตนเองได้
Delivery
Delivery
Singapore
1-3 work days ( 90% of Shipments)
For items that are stocked outside Singapore, it takes 7 - 14 work days.
International
7-14 work days.
Pick FEDEX at checkout for reliable and Fast Deliveries.
Taxes
Taxes
Singapore
GST Not Applicable - Prices displayed are final prices.
International
As per importering country's Duties and taxes. To be paid to Carrier or Customs Dept. Importer is responsible for Import Duty and Taxes.
แผ่นข้อมูล
แผ่นข้อมูล
cs@delight.com.sg
Tel: +65 6429 8402
Whatsapp: +65 8900 0895
We admit ! For Technical Clarifications, our AI BOT is Quicker than us. Try it !
แบ่งปัน
Features :
- AC input range selected by switch
- Built-in passive PFC function compliance to EN61000-3-2
- With AC ON-OFF switch
- 3 poles AC inlet with fuse holder
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Charger type can be selected (Optional}
- Charger for lead-acid batteries
- 2 color LED loading indicator
- Open frame models available (Without safety approval}
- Low cost, High reliability

SPECIFICATION
|
MODEL |
PA/PB-120 -13 |
PA/PB-120 -27 |
PA/PB-120 -54 |
||
|
OUTPUT |
DC VOLTAGE |
13.8V |
27.6V |
55.2V |
|
|
RATED CURRENT |
7.2A |
4.3A |
2.2A |
||
|
CURRENT RANGE |
0 ~ 7.2A |
0 ~ 4.3A |
0 ~ 2.2A |
||
|
RATED POWER |
99.36W |
118.68W |
121.44W |
||
|
LED INDICATED |
PA series voltage 105% 1% : RED / 105% 1% :GREEN |
||||
|
PB series load 46% 10% : GREEN / 46% 10% :RED |
|||||
|
INPUT |
VOLTAGE RANGE |
88 ~ 132VAC / 176 ~ 264VAC selected by switch |
|||
|
FREQUENCY RANGE |
47 ~ 63Hz |
||||
|
POWER FACTOR (Typ.) |
>0.65 (with PFC series) |
||||
|
EFFICIENCY (Typ.) |
73% |
79% |
79% |
||
|
AC CURRENT (Typ.) |
3A/115VAC 1.5A/230VAC |
||||
|
INRUSH CURRENT (Typ.) |
COLD START 25A/115VAC 50A/230VAC |
||||
|
LEAKAGE CURRENT |
<1.5mA / 240VAC |
||||
|
PROTECTION |
OVERLOAD |
90 ~ 110% rated output power |
|||
|
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|||||
|
OVER VOLTAGE |
15 ~ 17V |
30 ~ 35V |
60 ~ 66V |
||
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||||
|
OVER TEMPERATURE |
RTH2 70 10 detect on RTH2 thermistor |
||||
|
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
|||||
|
ENVIRONMENT |
WORKING TEMP. |
-10 ~ +45 (Refer to output load derating curve) |
|||
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||||
|
STORAGE TEMP., HUMIDITY |
-20 ~ +85 , 10 ~ 95% RH |
||||
|
TEMP. COEFFICIENT |
0.05%/ (0 ~ 45 |
|
|||
|
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
||||
|
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1, EN60335, EN60335-1, EN60335-2-29 approved |
|||
|
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||||
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
||||
|
EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
||||
|
HARMONIC CURRENT |
Compliance to EN61000-3-2,-3 |
||||
|
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A |
||||
|
OTHERS |
MTBF |
149.6K hrs min. MIL-HDBK-217F (25 ) |
|||
|
DIMENSION |
PCB Type:144*90*33mm External case type:180*96*49mm (L*W*H) |
||||
|
PACKING |
1.1Kg; 16pcs / 17.9Kg / 1.47CUFT(without PFC) 1.24Kg; 16pcs / 20.1Kg / 1.47CUFT(with PFC) |
||||
|
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. With PFC I/P range: 95~132VAC/190~264VAC. 6. For open P.C.B. WITH 17.8CFM min. Forced air. |
||||