S7
MEANWELL HEP Series Constant Voltage Power Supply
MEANWELL HEP Series Constant Voltage Power Supply
SKU:HEP-320-24A
ไม่สามารถโหลดความพร้อมในการรับสินค้าด้วยตนเองได้
Delivery
Delivery
Singapore
1-3 work days ( 90% of Shipments)
For items that are stocked outside Singapore, it takes 7 - 14 work days.
International
7-14 work days.
Pick FEDEX at checkout for reliable and Fast Deliveries.
Taxes
Taxes
Singapore
GST Not Applicable - Prices displayed are final prices.
International
As per importering country's Duties and taxes. To be paid to Carrier or Customs Dept. Importer is responsible for Import Duty and Taxes.
แผ่นข้อมูล
แผ่นข้อมูล
cs@delight.com.sg
Tel: +65 6429 8402
Whatsapp: +65 8900 0895
We admit ! For Technical Clarifications, our AI BOT is Quicker than us. Try it !
แบ่งปัน
Datasheet
Features:
- Universal AC input / Full range(up to 305VAC}
- Built-in active PFC function
- High efficiency up to 95%
- Fanless design, cooling by free air convection
- -55~+70℃ wide operating range
- Aluminum case and filling with heat-conducted silicone
- IP65 design, optional IP68 rated model available
- Meet 6KV surge immunity level
- Withstand 10G vibration test
- Operating altitude up to 5000 meters (Note.8}
- Protections: Short circuit / Overload / Over voltage / Over temperature
Applications:
- Outdoor telecommunication equipment
- Outdoor electronic signage and billboard
- Petroleum plant or mine shaft facility
Description:
HEP-320 is a 320W industrial AC/DC power supply featuring the outstanding capability to operate under a harsh environment with high dust density, humidity, vibration and altitude. The entire series is housed with a robust aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 95%, enabling HEP-320, with a fanless design, perfectly work between -55℃ and +70℃ under free air convection
{ A : Standard model, IP65, Vo and o level can be adjusted through internal potentiometer.
Blank : Optional model, IP68, with fixed Vo and Io level}
SPECIFICATION:Model HEP-320-24A
|
MODEL |
HEP-320-12 |
HEP-320-15 |
HEP-320-24 |
HEP-320-36 |
HEP-320-48 |
HEP-320-54 |
|
|
OUTPUT |
DC VOLTAGE |
12V |
15V |
24V |
36V |
48V |
54V |
|
RATED CURRENT |
22A |
19A |
13.34A |
8.9A |
6.7A |
5.95A |
|
|
RATED POWER |
264W |
285W |
320.16W |
320.4W |
321.6W |
321.3W |
|
|
RIPPLE & NOISE (max.) Note.2 |
150mVp-p |
150mVp-p |
150mVp-p |
250mVp-p |
250mVp-p |
350mVp-p |
|
|
VOLTAGE ADJ. RANGE Note.5 |
10.8 ~ 13.5V |
13.5 ~ 17V |
21 ~ 26V |
32 ~ 39V |
43 ~ 52V |
49 ~ 58V |
|
|
CURRENT ADJ. RANGE Note.5 |
11 ~ 22A |
9.5 ~ 19A |
6.67 ~ 13.34A |
4.45 ~ 8.9A |
3.35 ~ 6.7A |
2.97 ~ 5.95A |
|
|
VOLTAGE TOLERANCE Note.3 |
±3.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|
|
LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
|
LOAD REGULATION |
±2.0% |
±1.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
|
SETUP, RISE TIME Note.6 |
2500ms,80ms/115VAC 500ms,80ms/230VAC at full load |
||||||
|
HOLD UP TIME (Typ.) |
15ms at full load 230VAC /115VAC |
||||||
|
INPUT |
VOLTAGE RANGE Note.4 |
90 ~ 305VAC 127 ~ 431VDC |
|||||
|
FREQUENCY RANGE |
47 ~ 63Hz |
||||||
|
POWER FACTOR (Typ.) |
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.94/277VAC at full load |
||||||
|
EFFICIENCY (Typ.) |
91% |
92.5% |
94% |
94% |
94.5% |
95% |
|
|
AC CURRENT (Typ.) |
3.5A / 115VAC 1.65A / 230VAC 1.45A / 277VAC |
||||||
|
INRUSH CURRENT(Typ.) |
COLD START 70A at 230VAC |
||||||
|
LEAKAGE CURRENT |
<0.75mA / 277VAC |
||||||
|
PROTECTION |
OVER CURRENT |
105 ~ 125% |
|||||
|
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||||||
|
SHORT CIRCUIT |
Hiccup mode, recovers automatically after fault condition is removed |
||||||
|
OVER VOLTAGE |
14 ~ 17V |
17.5 ~ 21V |
27 ~ 33V |
40 ~ 46V |
53.5 ~ 60V |
59 ~ 65V |
|
|
Protection type : Shut down and latch off o/p voltage, re-power on to recover |
|||||||
|
OVER TEMPERATURE |
Shut down and latch off o/p voltage, re-power on to recover |
||||||
|
ENVIRONMENT |
WORKING TEMP. |
-55 ~ +70℃ (Refer to "Derating Curve") |
|||||
|
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
||||||
|
STORAGE TEMP., HUMIDITY |
-60 ~ +80℃, 10 ~ 95% RH non-condensing |
||||||
|
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 60℃) |
||||||
|
VIBRATION |
20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes |
||||||
|
SAFETY & EMC |
SAFETY STANDARDS Note.8 |
UL60950-1, IP65 (or IP68 for HEP-320 Blank-Type), EAC TP TC 004 approved ; design refer to TUV EN60950-1 |
|||||
|
WITHSTAND VOLTAGE |
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC |
||||||
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
||||||
|
EMC EMISSION |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 |
||||||
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level (surge 6KV), criteria A, EAC TP TC 020 |
||||||
|
OTHERS |
MTBF |
154.2K hrs min. MIL-HDBK-217F (25℃) |
|||||
|
DIMENSION |
252*90*43.8mm (L*W*H) |
||||||
|
PACKING |
1.88Kg; 8pcs/16Kg/0.92CUFT |
||||||
|
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the static characteristics for more details. 5. A-type only. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 8. The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month. 9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}. |
||||||