S7
MEANWELL DRH Series Rail Mount Power Supply
MEANWELL DRH Series Rail Mount Power Supply
SKU:DRH-120-24
ไม่สามารถโหลดความพร้อมในการรับสินค้าด้วยตนเองได้
Delivery
Delivery
Singapore
1-3 work days ( 90% of Shipments)
For items that are stocked outside Singapore, it takes 7 - 14 work days.
International
7-14 work days.
Pick FEDEX at checkout for reliable and Fast Deliveries.
Taxes
Taxes
Singapore
GST Not Applicable - Prices displayed are final prices.
International
As per importering country's Duties and taxes. To be paid to Carrier or Customs Dept. Importer is responsible for Import Duty and Taxes.
แผ่นข้อมูล
แผ่นข้อมูล
cs@delight.com.sg
Tel: +65 6429 8402
Whatsapp: +65 8900 0895
We admit ! For Technical Clarifications, our AI BOT is Quicker than us. Try it !
แบ่งปัน
Features :
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Built-in constant current limiting circuit
- Can be installed on DIN rail TS-35/7.5 or 15
- EN61000-6-2(EN50082-2} industrial immunity level
- 100% full load burn-in test
- Fixed switching frequency at 70KHz
Specification:
|
MODEL |
DRH-120-24 |
DRH-120-48 |
|
|
OUTPUT |
DC VOLTAGE |
24V |
48V |
|
RATED CURRENT |
5A |
2.5A |
|
|
CURRENT RANGE |
0 ~ 5A |
0 ~2.5A |
|
|
RATED POWER |
120W |
120W |
|
|
RIPPLE & NOISE (max.) Note.2 |
80mVp-p |
80mVp-p |
|
|
VOLTAGE ADJ. RANGE |
24 ~ 28V |
48 ~ 55V |
|
|
VOLTAGE TOLERANCE Note.3 |
±1.0% |
±1.0% |
|
|
LINE REGULATION |
±0.5% |
±0.5% |
|
|
LOAD REGULATION |
±0.5% |
±0.5% |
|
|
SETUP, RISE, HOLD UP TIME |
1700ms, 120ms, 16ms/400VAC 1000ms, 120ms, 30ms/500VAC at full load |
||
|
INPUT |
VOLTAGE RANGE |
340 ~ 550VAC 480 ~ 780VDC |
|
|
FREQUENCY RANGE |
47 ~ 63Hz |
||
|
EFFICIENCY (Typ.) |
85% |
86% |
|
|
AC CURRENT |
0.65A/400VAC 0.6A/500VAC |
||
|
INRUSH CURRENT (max.) |
COLD START 50A |
||
|
LEAKAGE CURRENT |
<3.5mA / 530VAC |
||
|
PROTECTION |
OVERLOAD |
105 ~ 160% rated output power |
|
|
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
|||
|
OVER VOLTAGE |
30 ~ 36V |
59 ~ 66V |
|
|
Protection type : Shut down o/p voltage, re-power on to recover |
|||
|
OVER TEMPERATURE |
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down |
||
|
ENVIRONMENT |
WORKING TEMP. |
-20 ~ +60℃ (Refer to "Derating Curve") |
|
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||
|
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH |
||
|
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
||
|
VIBRATION |
Component: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting clip: Compliance to IEC60068-2-6 |
||
|
SAFETY & EMC (Note 4) |
SAFETY STANDARDS |
UL60950-1, EAC TP TC 004 approved, IEC60950-1 CB approved by SIQ |
|
|
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC |
||
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
||
|
EMC EMISSION |
Compliance to EN55011 (CISPR11), EN55032 (CISPR32), EN61204-3 Class B, EAC TP TC 020 |
||
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020 |
||
|
OTHERS |
MTBF |
178.7Khrs min. MIL-HDBK-217F (25℃) |
|
|
DIMENSION |
65.5*125.2*100mm (W*H*D) |
||
|
PACKING |
0.75Kg; 20pcs/16Kg/1.29CUFT |
||
|
NOTE |
1. All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}. |
||