1
/
จาก
1
S7N2C12F2
ABB AX150-30-11-84 Block Contactor
ABB AX150-30-11-84 Block Contactor
SKU:7320500500170
ราคาปกติ
$ 336.00 SGD
ราคาปกติ
$ 336.00 SGD
ราคาโปรโมชัน
$ 336.00 SGD
ค่าจัดส่งที่คำนวณในขั้นตอนการชำระเงิน
ปริมาณ
ไม่สามารถโหลดความพร้อมในการรับสินค้าด้วยตนเองได้
Delivery
Delivery
Singapore
1-3 work days ( 90% of Shipments)
For items that are stocked outside Singapore, it takes 7 - 14 work days.
International
7-14 work days.
Pick FEDEX at checkout for reliable and Fast Deliveries.
Taxes
Taxes
Singapore
GST Not Applicable - Prices displayed are final prices.
International
As per importering country's Duties and taxes. To be paid to Carrier or Customs Dept. Importer is responsible for Import Duty and Taxes.
แผ่นข้อมูล
แผ่นข้อมูล
cs@delight.com.sg
Tel: +65 6429 8402
Whatsapp: +65 8900 0895
We admit ! For Technical Clarifications, our AI BOT is Quicker than us. Try it !
แบ่งปัน
Technical Details
Lead time 6-7 weeks.
AX150-30-11-84
General Information
-
- Extended Product Type:
- AX150-30-11-84
-
- Product ID:
- 1SFL991074R8411
-
- EAN:
- 7320500500170
-
- Catalog Description:
- AX150-30-11-84 Contactor
-
- Long Description:
- AX150-30-11-84 Contactor
Categories
Ordering
-
- Minimum Order Quantity:
- 1 piece
-
- Customs Tariff Number:
- 85364900
Popular Downloads
-
- Instructions and Manuals:
-
9AKK107492A7060
Dimensions
-
- Product Net Width:
-
102 mm
-
- Product Net Depth / Length:
-
123.5 mm
-
- Product Net Height:
-
148 mm
-
- Product Net Weight:
-
1.9 kg
Technical
-
- Number of Main Contacts NO:
- 3
-
- Number of Main Contacts NC:
- 0
-
- Number of Auxiliary Contacts NO:
- 1
-
- Number of Auxiliary Contacts NC:
- 1
-
- Rated Operational Voltage:
- Main Circuit 1000 V
-
- Rated Frequency (f):
- Main Circuit 50 Hz
-
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 190 A
-
- Rated Operational Current AC-1 (Ie):
- (690 V) 40 °C 190
(690 V) 55 °C 145
(690 V) 70 °C 130
-
- Rated Operational Current AC-3 (Ie):
- (415 V) 55 °C 150 A
(440 V) 55 °C 100 A
(500 V) 55 °C 100 A
(690 V) 55 °C 82 A
(380 / 400 V) 55 °C 150 A
(220 / 230 / 240 V) 55 °C 150
-
- Rated Operational Power AC-3 (Pe):
- (415 V) 75 kW
(440 V) 59 kW
(500 V) 59 kW
(690 V) 75 kW
(380 / 400 V) 75 kW
(220 / 230 / 240 V) 45 kW
-
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
- 8 x Ie AC-3
-
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
- 10 x Ie AC-3
-
- Rated Short-time Withstand Current (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
-
- Maximum Electrical Switching Frequency:
- 300 cycles per hour
-
- Rated Insulation Voltage (Ui):
- acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
-
- Rated Impulse Withstand Voltage (Up):
- 8 kV
-
- Mechanical Durability:
- 10 million
-
- Maximum Mechanical Switching Frequency:
- 3600 cycles per hour
-
- Coil Operating Limits:
- (acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
-
- Rated Control Circuit Voltage (Uc):
- 50 Hz 110 V
60 Hz 110 ... 120 V
-
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
-
- Terminal Type:
- Main Circuit: Bars