M4
ABB AX12-30-01-81 24V 50/60Hz Block Contactor
ABB AX12-30-01-81 24V 50/60Hz Block Contactor
SKU SKU:3471522394811
ราคาปกติ
$ 36.00 SGD
ราคาปกติ
$ 39.00 SGD
ราคาโปรโมชัน
$ 36.00 SGD
ราคาต่อหน่วย
/
ต่อ
แบ่งปัน
Technical Details
AX12-30-01-81
General Information
-
- Extended Product Type:
- AX12-30-01-81
-
- Product ID:
- 1SBL911074R8101
-
- EAN:
- 3471522394811
-
- Catalog Description:
- AX12-30-01-81 24V 50/60Hz Contactor
-
- Long Description:
- AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Categories
- Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors
Ordering
-
- Minimum Order Quantity:
- 1 piece
-
- Customs Tariff Number:
- 85364900
Popular Downloads
-
- Instructions and Manuals:
-
9AKK107492A7057
Dimensions
-
- Product Net Width:
-
44 mm
-
- Product Net Depth / Length:
-
74 mm
-
- Product Net Height:
-
74 mm
-
- Product Net Weight:
-
0.326 kg
Technical
-
- Number of Main Contacts NO:
- 3
-
- Number of Main Contacts NC:
- 0
-
- Number of Auxiliary Contacts NO:
- 0
-
- Number of Auxiliary Contacts NC:
- 1
-
- Rated Operational Voltage:
- Auxiliary Circuit 690 V
Main Circuit 690 V
-
- Rated Frequency (f):
- Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
-
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 26 A
acc. to IEC 60947-5-1, q = 40 °C 16 A
-
- Rated Operational Current AC-1 (Ie):
- (220 / 240 V) 55 °C 22 A
(690 V) 40 °C 25 A
(690 V) 70 °C 18 A
-
- Rated Operational Current AC-3 (Ie):
- (415 V) 55 °C 12 A
(440 V) 55 °C 9 A
(500 V) 55 °C 9 A
(690 V) 55 °C 7 A
(380 / 400 V) 55 °C 12 A
(220 / 230 / 240 V) 55 °C 12 A
-
- Rated Operational Power AC-3 (Pe):
- (415 V) 5.5 kW
(440 V) 4 kW
(500 V) 5.5 kW
(690 V) 5.5 kW
(380 / 400 V) 5.5 kW
(220 / 230 / 240 V) 3 kW
-
- Rated Operational Current AC-15 (Ie):
- (500 V) NC 2
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
(400 / 440 V) 2 A
-
- Rated Short-time Withstand Current Low Voltage (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A
for 0.1 s 140 A
for 1 s 100 A
-
- Maximum Breaking Capacity:
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
-
- Maximum Electrical Switching Frequency:
- (AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
-
- Rated Operational Current DC-13 (Ie):
- (24 V) 6 A / 144 W
(110 V) 1.1 A / 121 W
(125 V) 1.1 A / 138 W
(220 V) 0.55 A / 121 W
(250 V) 0.55 A / 138 W
(400 V) 2.8 A / 134 W
(500 V) 2 A / 144 W
-
- Rated Insulation Voltage (Ui):
- acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
-
- Rated Impulse Withstand Voltage (Uimp):
- Auxiliary Circuit 6 kV
-
- Maximum Mechanical Switching Frequency:
- 3600 cycles per hour
-
- Rated Control Circuit Voltage (Uc):
- 50 Hz 24 V
60 Hz 24 V
-
- Operate Time:
- Between Coil De-energization and NC Contact Closing 9 ... 16 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NC Contact Opening 7 ... 21 ms
Between Coil Energization and NO Contact Closing 10 ... 26 ms
-
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
IP20
-
- Terminal Type:
- Screw Terminals
Technical UL/CSA
-
- General Use Rating UL/CSA:
- (600 V AC) 25 A
-
- Horsepower Rating UL/CSA:
- (120 V AC) Single Phase 3/4 hp
(200 ... 208 V AC) Three Phase 3 hp
(220 ... 240 V AC) Three Phase 3 hp
(240 V AC) Single Phase 2 hp
(440 ... 480 V AC) Three Phase 7.5 hp
(550 ... 600 V AC) Three Phase 10 hp
-
- Tightening Torque UL/CSA:
- Auxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 9 in·lb
Environmental
-
- Ambient Air Temperature:
- Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... 70 °C
-
- Climatic Withstand:
- acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
-
- Maximum Operating Altitude Permissible:
- 3000 m
-
- RoHS Status:
- Following EU Directive 2002/95/EC August 18, 2005 and amendment
Certificates and Declarations (Document Number)
-
- CB Certificate:
-
9AKK107492A7072
-
- CCC Certificate:
-
9AKK107492A7089
-
- CCS Certificate:
-
9AKK107492A7096
-
- CQC Certificate:
-
CQC2013010304646608
-
- Declaration of Conformity - CCC:
-
2020980304001066
-
- Declaration of Conformity - CE:
-
1SBD250011U1000
-
- Instructions and Manuals:
-
9AKK107492A7057
-
- RoHS Information:
-
1SBD251301E1000
Container Information
-
- Package Level 1 Units:
- 1 piece
-
- Package Level 1 Width:
- 48 mm
-
- Package Level 1 Depth / Length:
- 78 mm
-
- Package Level 1 Height:
- 79 mm
-
- Package Level 1 Gross Weight:
- 0.34 kg
-
- Package Level 1 EAN:
- 3471522394811
-
- Package Level 2 Units:
- 30 piece
-
- Package Level 2 Width:
- 240 mm
-
- Package Level 2 Depth / Length:
- 295 mm
-
- Package Level 2 Height:
- 145 mm
-
- Package Level 2 Gross Weight:
- 10.2 kg
Classifications
-
- Object Classification Code:
- Q
-
- ETIM 6:
- EC000066 - Power contactor, AC switching
-
- ETIM 7:
- EC000066 - Power contactor, AC switching
-
- UNSPSC:
- 39121529
-
- IDEA Granular Category Code (IGCC):
- 4755 >> Contactors
-
- E-Number (Finland):
- 3707310